Elkart Brass Manufacturing Co. No. 211 Firefighting Nozzle: A Technical and Historical Appraisal of a Mid-Century American Brass Hose Nozzle
A detailed examination of the Elkart Brass Manufacturing Co. No. 211 adjustable-pattern fire nozzle — including its brass composition, threaded specifications, operational mechanics, historical context, restoration protocols, and collector significance.

The Elkart Brass Manufacturing Co. No. 211 is a precision-crafted, mid-20th-century adjustable-pattern fire nozzle produced between 1948 and 1963 in Elkhart, Indiana. Constructed entirely from solid yellow brass (CDA Alloy 260), it features a 1¼-inch National Pipe Thread (NPT) male inlet, a rotating brass collar with engraved flow settings (0–100 psi), and a dual-function shutoff valve integrated into the handle assembly. Weighing precisely 4.2 pounds (1.91 kg), it delivers a 30° fog pattern at 50 psi and a solid stream reaching 72 feet horizontally at 100 psi. This article provides technical documentation, metallurgical analysis, manufacturing history, field performance data, and conservation methodology specific to this iconic piece of firefighting hardware.
Historical Context and Corporate Provenance
Elkart Brass Manufacturing Co. was founded in 1922 by William H. Schrader and operated independently until its acquisition by Grinnell Corporation in 1963. The company’s factory occupied a 12-acre site on South Main Street in Elkhart, Indiana — a location that remained operational for over four decades. Unlike many contemporaries who sourced castings from foundries, Elkart maintained full vertical integration: brass billets were rolled on-site, extruded into nozzle blanks, machined on Brown & Sharpe turret lathes, and hand-finished by skilled toolmakers trained under the U.S. Navy’s wartime apprenticeship program.
Production records archived at the Elkhart County Historical Museum confirm that the No. 211 model entered serial production in March 1948, following successful field trials with the Chicago Fire Department and the U.S. Forest Service. It replaced the earlier No. 107 ‘Vortex’ nozzle due to superior pressure regulation and reduced operator fatigue during extended use. By 1957, over 42,300 units had been shipped to municipal fire departments across 41 states, with documented installations in New York City (FDNY Engine Company 12), Los Angeles County Fire Department (Station 28), and the Houston Fire Department (Ladder 14).
Design Evolution Within the Elkart Lineage
The No. 211 represented the third generation of Elkart’s adjustable-pattern nozzles. Its predecessor, the No. 107 (1941–1947), used a spring-loaded toggle mechanism prone to jamming when exposed to freezing temperatures. The No. 211 introduced a patented cam-and-groove actuation system — filed under U.S. Patent No. 2,537,194 (granted January 9, 1951) — which eliminated reliance on compression springs and instead utilized hardened steel cams embedded within the brass housing. This innovation increased service life from an average of 8.2 years (No. 107) to 14.6 years (No. 211), per FDNY maintenance logs archived at the Brooklyn Fire Academy.
Elkart’s engineering team also incorporated a tapered inlet bore — 1.22 inches at the thread base narrowing to 1.12 inches at the valve seat — to reduce turbulence and improve laminar flow. This design choice, validated through water tunnel testing at Purdue University’s Hydraulics Lab in 1949, yielded a 12.7% increase in volumetric efficiency compared to the standard 1¼-inch smooth-bore nozzles then in service.
Material Composition and Metallurgical Specifications
All No. 211 nozzles were manufactured exclusively from CDA Alloy 260 (also known as cartridge brass), a copper-zinc alloy containing 70% copper and 30% zinc by weight. This composition was selected for its optimal balance of tensile strength (53,000 psi), elongation (65%), and corrosion resistance in chlorinated municipal water supplies. Crucially, CDA 260 exhibits negligible dezincification in freshwater environments — a critical factor given that municipal hydrants routinely deliver water with pH levels ranging from 6.8 to 8.3.
Each casting underwent triple-stage quality verification: first, ultrasonic thickness mapping to ensure minimum wall thickness of 0.285 inches at all stress points; second, hydrostatic pressure testing at 300 psi for 120 seconds without leakage; third, dimensional inspection using Mitutoyo 500-196-30 coordinate measuring equipment calibrated to NIST Traceable Standards. These protocols exceeded NFPA 1963 (1954 edition) requirements by 40%, establishing Elkart as a benchmark for durability.
Thread Geometry and Interchangeability
The No. 211 utilizes a 1¼-inch National Pipe Thread (NPT) male inlet conforming to ANSI B1.20.1-1955 standards. Its thread pitch is exactly 11.5 threads per inch (TPI), with a taper of 1:16 (0.0625 inches per inch). The root diameter measures 1.154 inches ±0.002 inches, while the major diameter is 1.375 inches ±0.002 inches. These tolerances ensured compatibility not only with standard 1¼-inch fire hose couplings but also with legacy systems such as the 1927 American LaFrance Type E coupling and the 1939 Darley ‘Quick-Lock’ adapter.
This precise threading allowed seamless integration with contemporary pumpers: the 1952 Seagrave 700 Series, the 1955 Mack B Model, and the 1959 Ward LaFrance 800 Series all specified Elkart No. 211 nozzles in their OEM equipment lists. Field reports from the Ohio State Fire Marshal’s Office (1956–1961) indicate zero incidents of thread stripping or galling despite repeated thermal cycling between ambient temperatures and 180°F discharge water.
Mechanical Operation and Hydraulic Performance
The No. 211 operates via a dual-lever control system housed within a one-piece brass body. The primary lever — located on the right side — rotates a hardened steel cam (Rockwell C-58) that modulates the position of a forged bronze impeller ring. This ring controls the annular gap between the nozzle’s inner cone and outer sleeve, thereby adjusting spray pattern from straight stream (0° divergence) to wide fog (120° divergence). A secondary thumbwheel on the left side engages a positive-stop gate valve that fully occludes flow without requiring excessive torque.
Hydraulic testing conducted by Underwriters Laboratories in 1953 established the following certified performance metrics at 100 psi inlet pressure:
- Solid stream reach: 72 feet horizontal distance (±2.3 ft)
- Fog pattern width at 20 feet: 18.4 feet (±0.6 ft)
- Flow rate at 50 psi: 125 gallons per minute (GPM) ±3.1 GPM
- Flow rate at 100 psi: 228 GPM ±4.7 GPM
- Reaction force at 100 psi: 48.2 pounds-force (lbf) ±1.9 lbf
These figures were verified across three independent test cycles using calibrated Venturi meters traceable to NIST Standard Reference Material 2790. Notably, the No. 211 achieved a coefficient of discharge (Cd) of 0.971 — significantly higher than the industry average of 0.924 for brass nozzles of equivalent size — due to its optimized internal contouring and absence of sharp-edged transitions.
Valve Mechanism Engineering
The shutoff valve employs a modified ball-valve architecture adapted for high-flow firefighting applications. Instead of a spherical closure element, the No. 211 uses a toroidal stainless steel disc (Type 304, 0.092 inches thick) mounted on a 0.375-inch-diameter hardened steel shaft. Rotation of the thumbwheel moves the disc perpendicular to flow direction, achieving complete closure in 85° of travel. Sealing is accomplished via two concentric Viton® O-rings (AS568A-207, durometer 75 Shore A) compressed against machined brass seats with surface roughness Ra ≤ 0.4 µm.
Accelerated wear testing demonstrated that these O-rings retained functional integrity after 12,800 open/close cycles — surpassing NFPA 1963’s requirement of 5,000 cycles by 156%. Replacement O-rings remain commercially available from Parker Hannifin (P/N V75-70-207) and Greene Tweed (P/N ARKON-207), ensuring long-term maintainability.
Identification and Serial Number Protocol
Every authentic Elkart No. 211 bears three permanent identifiers stamped with diamond-point dies:
- A raised ‘ELKART BRASS MFG CO.’ logo on the upper rear flange
- A model designation ‘NO. 211’ centered beneath the logo
- A six-digit sequential serial number on the underside of the handle near the pivot pin
Serial numbers began at 000001 in March 1948 and concluded at 423187 in December 1963. Production logs reveal that serial ranges correspond to calendar quarters: for example, numbers 184220–209145 denote units built between Q3 1955 and Q2 1956. Units bearing ‘GRINNELL’ stamps post-1963 are rebranded No. 211s — identical in construction but lacking the original Elkart die stamp on the flange.
Counterfeit examples — predominantly fabricated in Pakistan and China since the early 2000s — can be identified by inconsistencies including:
- Use of CDA Alloy 270 (63% Cu, 37% Zn) resulting in reddish tint and lower tensile strength (42,000 psi) Abnormal thread pitch (11.25 TPI or 11.75 TPI instead of exact 11.5 TPI)
- Serial numbers exceeding 423187 or formatted with alphabetic prefixes (e.g., ‘EB211-A12345’)
- Absence of the original ‘MADE IN USA’ stamp below the serial number
| Feature | Authentic Elkart No. 211 | Common Counterfeit Indicator |
|---|---|---|
| Brass Alloy | CDA 260 (70/30 Cu/Zn) | CDA 270 or unknown alloy; spectral analysis shows Fe > 0.1% |
| Weight | 4.20 ± 0.03 lbs (1.905–1.912 kg) | 3.85–4.05 lbs (inconsistent casting density) |
| Thread Pitch | Exactly 11.5 TPI (verified with thread plug gauge) | 11.25 or 11.75 TPI (measured with optical comparator) |
| Engraving Depth | 0.012–0.015 inches (uniform, crisp edges) | 0.006–0.009 inches (fuzzy, shallow, inconsistent) |
| O-Ring Groove Finish | Ra ≤ 0.4 µm (mirror-polished) | Ra ≥ 1.6 µm (visible machining marks) |
Restoration Methodology and Conservation Ethics
Restoring a No. 211 requires adherence to ASTM E2841-12 (Standard Practice for Conservation Treatment of Historic Fire Apparatus) and avoidance of abrasive media blasting or electrolytic cleaning, both of which compromise the brass’s protective patina and underlying grain structure. The recommended sequence begins with mechanical decontamination using nylon bristle brushes and deionized water, followed by ultrasonic cleaning in a 3% ammonium citrate solution (pH 4.2) for 12 minutes at 45°C.
Corrosion removal must target only active dezincification (white powdery residue) using a custom chelating paste: 12.5 g ethylenediaminetetraacetic acid (EDTA), 7.5 g sodium bicarbonate, and 80 mL deionized water. Applied for 90 seconds with cotton swabs, this formulation selectively dissolves zinc-rich corrosion products without attacking the copper matrix. Post-treatment rinsing requires triple immersion in deionized water followed by ethanol dehydration.
Reassembly and Functional Verification
Original replacement parts are essential: Viton® O-rings (Parker P/N V75-70-207), stainless steel cam pins (McMaster-Carr P/N 98103A125), and phosphor bronze thrust washers (ASTM B139 Grade C51000). Torque specifications must be strictly observed: the inlet coupling nut requires 42 ft-lbf (per SAE J1920), while the handle pivot screw demands 14.5 in-lbf (verified with Tohnichi MTB15CN torque screwdriver).
Functional verification includes three mandatory tests:
- Leak test: 200 psi static pressure for 5 minutes (zero leakage at all joints)
- Pattern calibration: Laser-confirmed divergence angles at 100 psi using Keyence LK-G3000 series sensor
- Flow verification: Gravimetric measurement against NIST-traceable Coriolis mass flow meter (±0.8% accuracy)
Upon successful completion, the nozzle receives a conservation label affixed to the interior of the handle: black laser-etched titanium foil (0.005 inches thick) with QR code linking to archival documentation, including date of restoration, technician ID, and material certification numbers.
Collector Value and Institutional Significance
The No. 211 holds exceptional status among firefighting memorabilia collectors. In 2023, a fully documented, unrestored unit with original leather carrying strap and 1954 FDNY Station 38 provenance sold at Morphy Auctions for $2,875. Units with intact factory packaging — rare cardboard box lined with waxed kraft paper, stamped ‘ELKART BRASS / NO. 211 / TESTED AND GUARANTEED’ — command premiums of 300–400% over bare units.
Institutionally, the No. 211 appears in permanent collections at the National Fire Museum (Lansing, MI), the San Francisco Fire Commission Archives, and the Smithsonian Institution’s Division of Work and Industry (Object ID AF.245891). Its inclusion reflects recognition of Elkart’s contribution to hydraulic engineering standardization: the company’s 1952 white paper ‘Dynamic Flow Modulation in Fixed-Pattern Nozzles’ directly informed revisions to NFPA 1963 Section 5.4 (Adjustable Pattern Devices), adopted nationally in 1957.
Contemporary relevance persists beyond nostalgia. Modern nozzle manufacturers including Task Force Tips and TFT continue to reference Elkart’s cam-profile geometry in computational fluid dynamics modeling. A 2021 study published in Fire Technology (Vol. 57, pp. 1123–1141) confirmed that the No. 211’s internal taper ratio (1.22:1.12) remains the most efficient configuration for minimizing cavitation onset at flow rates between 120–240 GPM — validating seven decades of empirical design excellence.
Preservation efforts are coordinated through the Elkart Brass Preservation Society (EBPS), founded in 2008 by retired Grinnell engineers and FDNY apparatus officers. The EBPS maintains a digital registry of 3,217 verified No. 211 units, cross-referenced with service histories, restoration logs, and metallurgical assay reports. Membership includes access to proprietary CAD models derived from CT scans of museum-grade specimens — enabling precise replication of machining parameters for authentic spare parts.
Unlike decorative brass antiques, the No. 211 functions as a calibrated instrument whose historical value is inextricable from its measurable performance. Its enduring utility — evidenced by active use in volunteer departments across Appalachia and rural Maine — underscores a principle central to conservation ethics: authenticity resides not solely in age or provenance, but in verifiable continuity of purpose, material integrity, and engineered function.
For restorers, curators, and fire service historians, the No. 211 represents more than industrial archaeology. It embodies a convergence of wartime metallurgical advances, municipal infrastructure investment, and frontline operational pragmatism — all encoded in 4.2 pounds of precisely proportioned yellow brass. Its continued presence in training academies and museum galleries affirms that certain tools transcend obsolescence when their design achieves irreversible alignment with human need and physical law.
Documentation standards for No. 211 units follow ISO 18935:2017 (Imaging materials — Recommended practice for documenting historic apparatus). Each registered item requires photographic documentation from five fixed angles (front, rear, left, right, top), microphotography of the serial number (200× magnification), and spectral reflectance measurement across the CIE 1931 color space to quantify patina development. These datasets feed into the EBPS Long-Term Corrosion Modeling Project, which predicts service life extension under varying environmental exposures — from coastal salt-air to Midwest hard-water mineral deposition.
Technical literature remains accessible through the EBPS Digital Archive, which hosts scanned copies of Elkart’s 1950 ‘Operator’s Manual for No. 211 Adjustable Pattern Nozzle’ (Document EB-OPM-211-1950 Rev. 3), the 1959 ‘Maintenance Bulletin MB-211-59’, and Grinnell’s 1965 ‘Legacy Equipment Compatibility Guide’. All documents retain original pagination, ink formulations, and paper stock metadata — preserved not as static images, but as layered PDF/A-3 files with embedded XMP metadata describing substrate composition and printing method.
Current production of reproduction components adheres to ASTM B134-15 (Standard Specification for Brass Rod, Bar, and Shapes). Suppliers including Rotax Metals (Cleveland, OH) and Belmont Metals (Chicago, IL) certify their CDA 260 billets with mill test reports showing tensile strength ≥ 52,500 psi and elongation ≥ 63% — matching original Elkart specifications within 0.4% tolerance. This fidelity ensures that conservation interventions do not introduce material discontinuities compromising structural longevity.
The No. 211’s legacy endures because it solved a precise problem with unambiguous metrics: delivering predictable water application under variable pressure, with minimal operator input, using materials that resisted degradation across decades of service. Its continued relevance lies not in sentimentality, but in reproducible physics — a testament to engineering discipline where every dimension, alloy percentage, and surface finish served a quantifiable purpose.
More Like This

Authenticating and Preserving the Icart 'Scene from Faust' Lithograph: A 20 × 12½-Inch Signed Print in Original Frame

Advertising Pouch: Quadroon Cloth Image of Woman with Fan, 1883 (4 × 3 in)

Frankart Bookends Female Bust: Identification, Value, and Restoration Insights for Collectors

Edwardian Wing Chair Restoration Guide: Mahogany Frame, Leather Upholstery & Turned Legs

Windsor Fanback Chair with Six Spindles and Saddle Seat: A New England Masterpiece, Circa 1780

Gilt Bronze Figures: Craftsmanship, Provenance, and Conservation of 18th–19th Century French Bronzes

Decoding the 1134971: A Technical and Historical Analysis of the 1958 Baker Furniture Company 'Chippendale Revival' Mahogany Breakfront Bookcase

The 1900 GOP Elephant Pin: A Gold-Finished Political Artifact Featuring William McKinley

Bradley & Hubbard Oil Lamp: Brass Rococo Openwork Handles, Electrified Conversion & Restoration Insights